<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15394</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: carrier on drum
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Select CANCEL IMAGE from the workstation dialog box, and then
MANUALLY UNLOAD CARRIER from the TRANDSETTER pull-down menu.  If
this doesn't work, select MEDIA CLEARED from and remove the carrier
by hand (not recommended).  If the problem recurs, call Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error should only occur when calibrating the AD offset values and should not occur
during normal operation. Unloading the carrier using the diagnostic command "punload c" or the
workstation terminal should resolve the problem.
If the carrier is not on the drum, try turning proof mode off after a full reset by using:
"proof mode off" - then do another full reset and check using the "s" macro (status).
</text></DescriptionText>
</ServiceInformation>
<Cause>
Carrier unexpectedly left on the drum.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/punload.xml</LinkAddress><LinkTitle>Command: punload</LinkTitle></Link>
(see "punload c")
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:07 2008 PST
</Updated>
<Links>
</Links>
</Error>